建筑结构

2005, (05) 74-76

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Past Issue) | 高级检索(Advanced Search)

预应力混凝土框架结构抗震性能伪静力试验研究
Pseudostatic Tests on Seismic Performance of Prestressed Concrete Frame Structures

王红囡,周德源,吴晓涵
Wang Hongnan 1,Zhou Deyuan 2,Wu Xiaohan 2(1 Civ. Eng. Depart.,Shanghai Normal Univ.,Shanghai 201418,China; 2 Research Institute of Structure Engineering and Disaster Reduction,Tongji Univ.,Shanghai 200092,China)

摘要(Abstract):

进行了有粘结和无粘结预应力两榀混凝土框架结构在低周反复荷载作用下的伪静力实验。有粘结试件的梁端裂缝和柱脚裂缝均比无粘结试件要早,有粘结试件的破坏水平位移比无粘接的大。比较分析表明,两结构都表现出较好的延性和耗能能力,但有粘结件稍强一些。试验结果说明预应力框架的设计中应适当提高柱梁的强度比要求。
Two models of prestressed concrete frame structure Pf(with bonded tendons) and UPf(without bonded tendons) are pseudostaticly tested under low-reversed cyclic loading.The crack loads of the Pf at the end of beam and the column are smaller than those of the UPf,but the failure displacement is larger.Both structures have good ductility and energy dissipation capacity,but those of the Pf are better.The test results show that in the prestressed concrete frame structure design,the strength ratio of column to beam should be increased adequately.

关键词(KeyWords): 预应力混凝土;框架结构;抗震性能;延性
prestressed concrete; frame structure; seismic performance; ductility

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 王红囡,周德源,吴晓涵
Wang Hongnan 1,Zhou Deyuan 2,Wu Xiaohan 2(1 Civ. Eng. Depart.,Shanghai Normal Univ.,Shanghai 201418,China; 2 Research Institute of Structure Engineering and Disaster Reduction,Tongji Univ.,Shanghai 200092,China)

Email:

DOI: 10.19701/j.jzjg.2005.05.022